Parameters

Wire and cable: connectors, switches, sockets, computer cables, mouse wheels, telephone lines, mobile phone casing wires, electronic buttons, electrical supports or bases, Camera parts, mouse lines, electronics and more.

UL/CSA wire and cable

General requirements

 

 

 

 

model

unit

60℃ PVC

80℃ PVC

105℃ PVC

use

* * *

Insulation/Sheath

Insulation/Sheath

Insulation/Sheath

Reference standard

***

UL 1581

Table 50.182

UL 1581

Table 50.182

UL 1581

Table 50.182

Shore hardness (reference)

A

75-98

75 to 98

75-98

maximum color difference

△ And

1.0

1.0

1.0

Relative density

g/cm 3

≤1.45

≤1.45

≤1.45

physical properties

Minimum elongation before aging

%

100

100

150

Minimum elongation residual rate after aging

%

65

65

65

Maximum elongation change rate after aging

%

Minimum tensile strength before aging

Mpa

10.3

10.3

10.3

Minimum tensile residual rate after aging

%

70

70

70

Maximum Tensile Change Rate After Aging

%

-

one

Aging temperature and time

°C/h

100/168

113/168

136/168

Heat loss temperature and time

°C/h

100/168

113/168

136/168

heat loss max loss

mg/crr)2

2.0

2.0

2.0

High temperature pressure temperature and time

°C/h

121/1

121/1

121/1

High temperature pressure maximum deformation

%

50

50

50

High temperature winding temperature and time

°C/h

121/1

121/1

136/1

High temperature winding requirements

* * *

Does not crack

Does not crack

Does not crack

Low temperature bending temperature and time

°C/h

-10/1

-15/1

-20/1

Low temperature bending requirements

* * *

Does not crack

Does not crack

Does not crack

Low temperature elongation temperature and time

°C/h

-

Low temperature tensile minimum elongation

%

-

Oil resistance test temperature and time

°C/h

-

-

Oil resistance test requirements

°C/h

-

-

Thermal stability at 200°C

min

Electrical properties

Minimum volume resistance

Q.cm

one

one

Dielectric strength

MV/m

-

-

Flame retardant properties

Flame retardant grade (Cable)

* * *

VW-1

VW-1

VW-1

 

GB 3C wire and cable part

General requirements

 

 

 

 

model

unit

70℃ pvc

70℃ PVC

90℃ pvc

use

***

insulation

jacket

Insulation/Sheath

Reference standard

* * *

GB/T8815

GB/T8815

GB/T8815

Shore hardness (reference)

A

75-98

65-90

75-98

maximum color difference

△ And

1.0

1.0

1.0

Relative density

g/cm 3

≤1.45 ≤1.45 ≤1.45

physical properties

Minimum elongation before aging

%

150

180

150

Minimum elongation residual rate after aging

%

 

Maximum elongation change rate after aging

%

20

20

20

Minimum tensile strength before aging

Mpa

15

15

16

Minimum tensile residual rate after aging

%

-

 

Maximum Tensile Change Rate After Aging

%

20

20

20

Aging temperature and time

°C/h

100/168

100/168

135/240

Heat loss temperature and time

°C/h

100/168

100/168

115/240

heat loss max loss

mg/cm2

2.0

2.0

2.0

High temperature pressure temperature and time

°C/h

80/4

80/4

80/4

High temperature pressure maximum deformation

%

50

50

50

High temperature winding temperature and time

°C/h

150/1

150/1

150/1

High temperature winding requirements

***

Does not crack

Does not crack

Does not crack

Low temperature bending temperature and time

°C/h

 

Low temperature bending requirements

***

-

 

Low temperature elongation temperature and time

°C/h

-15/4

-15/4

-20/4

Low temperature tensile minimum elongation

%

30

30

30

Oil resistance test temperature and time

°C/h

-

Oil resistance test requirements

°C/h

-

Thermal stability at 200°C

min

≥60

≥60

≥80

Electrical properties

20°C minimum volume resistance

Oh.cm

1x1012

1x108

1x1012

Dielectric strength

MV/m

20

18

20

Flame retardant properties

Oxygen Index

%

Refer to GB/T2406-1993

Refer to GB/T2406-1993

Refer to GB/T2406-1993

European standard (VDE) wire and cable part

General requirements

 

 

 

 

model

unit

75℃ PVC

75℃ PVC

90℃ PVC

use

* * *

insulation

jacket

Insulation/Sheath

Reference standard

***

IEC 60227

IEC 60227

IEC 60227

Shore hardness (reference)

A

75-98

1.0

75-98

maximum color difference

△ And

1.0

545

1.0

Relative density

g/cm 3

≤1.45

 

≤1.45

physical properties

Minimum elongation before aging

%

125

150

150

Minimum elongation residual rate after aging

%

one

 

Maximum elongation change rate after aging

%

20

20

20

Minimum tensile strength before aging

Mpa

12.5

10

16

Minimum tensile residual rate after aging

%

-

 

Maximum Tensile Change Rate After Aging

%

20

20

20

Aging temperature and time

°C/h

80/168

80/168

135/240

Heat loss temperature and time

°C/h

80/168

80/168

115/240

heat loss max loss

mg/cm2

2.0

2.0

2.0

High temperature pressure temperature and time

°C/h

80/4

80/4

80/4

High temperature pressure maximum deformation

%

50

50

50

High temperature winding temperature and time

°C/h

150/1

150/1

150/1

High temperature winding requirements

* * *

Does not crack

Does not crack

Does not crack

Low temperature bending temperature and time

°C/h

 

Low temperature bending requirements

* * *

-

 

Low temperature elongation temperature and time

°C/h

-15/4

-15/4

-15/4

Low temperature tensile minimum elongation

%

30

30

30

Oil resistance test temperature and time

°C/h

-

 

Oil resistance test requirements

°C/h

 

Thermal stability at 200°C

min

-

>180

Electrical properties

Minimum volume resistance

Q.cm

1x1012

1x108

1x1012

Dielectric strength

MV/m

Flame retardant properties

Flame retardant grade (Cable) reference

* * *

FT2

FT2

FT2

 

11

We could not find any corresponding parameters, please add them to the properties table
Product consultation
Yuansu It is a professional R&D, production and sales TPE,TPR, TPV, TPU, XLPE, PVC environmentally friendly plastic manufacturing enterprise.
华阳精机
全部评论
已有0条评论
There is currently no content to display
Please add data record on website background.
gotop
Feedback
code
Yuansu

Qingcaowo Industrial Zone, Zhenlong, Huiyang District, Huizhou City

0752-3080683

copyright © Huizhou Yuansu Polymer Materials Co., Ltd.       粤ICP备15049429号

Power by:www.300.cn   SEO